Sanmin QG-Z-15 Solenoid Valve Pulse Jet Valve Pressure 0.3MPa - 0.6MPa Dust Proof Baghouse application GOYEN Type
Technical Parameter
Right angle | Embedded | Inline | Plug | |
Design-pressure | 0.3~0.8MPa | 0.2~0.8MPa | 0.3~0.8MPa | 0.2~1.0MPa |
Working-pressure | 0.3~0.6MPa | 0.2~0.6MPa | 0.3~0.6MPa | 0.2~0.6MPa |
Ambient Temperature | -25~60℃ Customized for lower or higher temperature | |||
Relative Humidity | ≤85% | |||
Working Medium | Clean Air | |||
Voltage | AC220V/DC24V/AC110V/AC24V Customized | |||
Protection Class | IP65 | |||
Diaphragm Life | Over One Million Cycles | |||
Cv/Kv | Call us for detail |
Material Construction :
Body : ADC12 die cast
Armature : 430 FR stainless steel
Diaphragm : Nitrile or Viton
Spring : 321 stainless steel
Fasteners : 302 stainless steel
Use period | Failure phenomena | Possible Reason | Troubleshooting |
During installation and commissioning | The valves cannot all be opened, but the leading part does act. | Check the gas dome pressure to see if it is too low. | Check the leakage |
Some valves do not work, but the others are normal. | Check the valve coil connection and coil | Replace the accessories | |
The valves cannot all be closed. There is leakage. There is no way to establish a gas dome. | Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves. | Check the leakage | |
Z-valve. The valve inlet and blowing muzzle are installed backwards. | Re-install | ||
Some valves cannot be closed. There is leakage. | There is some dirt or debris on the membrane, ii is blocking the moving iron core. | Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock. | |
A valve closing is slowly. | The membrane orifice is blocked. | Dredge the membrane orifice | |
During use period | Some valves are leaking. The membrane cannot close tightly and the valve is always open a little. | There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked. | Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary. |
Coil is hot and burned out. | It has been turned on for too long. | Check the working condition of the control system. | |
Voltage exists but the valve does not operate. | Membrane is damaged and the orifice is blocked. | Replace the accessories in time. | |
Ambient temperature is below -20℃. The valve is leaking and cannot open. | Ambient temperature is too low and here is frost in the valve. | Pay attention to insulation and maintaining proper temperatures. |
Our products are high quality with 12 month guarantee ,and support paypal payment.
Ningbo Sanmin Import And Export Co.,Ltd.
NINGBO SANMIN IMPORT & EXPORT CO.,LTD. was established in 2014.Our company is mainly engaged in instrumentation, pneumatic and hydraulic industry accessories and services, has more than 10 series of core products.Focusing on the production of automatic machinery to provide a variety of options, products have a wide range of applications.
Sanmin is an industrial and trade enterprise, has a strict quality control system from material selection, inspection workshop, product testing, production, inspection, packaging design to shipment.At present, the company's trade scale is expanding day by day, the customers spreads over more than 20 countries.
We are strictly abides by Chinese laws and regulations, and has won the trust of customers at home and abroad with good reputation. Welcome to telephone and send E-mail to communication, sincerely cooperate, and seek common development.
Supply Original FESTO,SMC,CKD,NORGEN,MARSH,BELLOFRAM,BELGAS,MUELLER,SBFEC.
NINGBO SANMIN IMPORT AND EXPORT CO.,LTD.
INA CHEN
Whatsapp/wechat: +86 15168536055
Desk phone :+86 0574 88915660
Skype: fhtrust